changeBlockStorageVolumeSize

Prev Next

Available in VPC

Change the volume size of block storage. For block storage that is assigned to a server, changes can only be made while the server instance is stopped. KVM-based block storage is not supported.

Syntax

The changeBlockStorageVolumeSize syntax is as follows:

./ncloud vserver changeBlockStorageVolumeSize \
    --blockStorageInstanceNo <block-storage-instance-no> \
    --blockStorageSize <block-storage-size> \
    [--regionCode <KR|SGN|JPN>] \
    [--output <json|xml>]

Options

This section describes the options available when running changeBlockStorageVolumeSize.

Required options

The following options are required for changeBlockStorageVolumeSize.

Options Type Required Description
--blockStorageInstanceNo String Required Block storage instance number
--blockStorageSize Integer Required Block storage size (GB)
  • 10-2000
  • Enter in 10 GB increments.
  • Can only be changed beyond the existing size.
  • Changes take effect after the server expands the file storage size.
  • See Change storage size.

Common options

For information about the options common to all vserver subcommands, see Server (VPC) options.

Examples

If the request to resize a block storage volume is successful, the identification information, along with the updated configuration and status information, is returned.

Command

The command example is as follows:

./ncloud vserver changeBlockStorageVolumeSize \
    --blockStorageInstanceNo 89012345 \
    --blockStorageSize 70 \
    --regionCode KR \
    --output json

Output

The output example is as follows:

{
  "changeBlockStorageVolumeSizeResponse": {
    "totalRows": 1,
    "blockStorageInstanceList": [
      {
        "blockStorageInstanceNo": "89012345",
        "blockStorageName": "test-block-storage-01",
        "blockStorageType": {
          "code": "SVRBS",
          "codeName": "Server BS"
        },
        "blockStorageSize": 75161927680,
        "blockStorageProductCode": "SPBSTBSTAD000006",
        "blockStorageInstanceStatus": {
          "code": "CREAT",
          "codeName": "Block storage CREATED status"
        },
        "blockStorageInstanceOperation": {
          "code": "CHNG",
          "codeName": "Block storage RESIZE OP"
        },
        "blockStorageInstanceStatusName": "changingSpec",
        "createDate": "2026-05-14T20:18:21+0900",
        "blockStorageDescription": "Test block storage",
        "blockStorageDiskType": {
          "code": "NET",
          "codeName": "Network storage"
        },
        "blockStorageDiskDetailType": {
          "code": "SSD",
          "codeName": "SSD"
        },
        "maxIopsThroughput": 4000,
        "isEncryptedVolume": false,
        "zoneCode": "KR-1",
        "regionCode": "KR",
        "isReturnProtection": false,
        "blockStorageVolumeType": {
          "code": "SSD",
          "codeName": "SSD"
        },
        "hypervisorType": {
          "code": "XEN",
          "codeName": "XEN"
        }
      }
    ],
    "requestId": "b3c4d5e6-f7a8-9012-cdef-678901234567",
    "returnCode": "0",
    "returnMessage": "success"
  }
}